Explore member advantages and opportunities!

Temperature calibration of thermomechanical analayzers: an interlaboratory test of the calibration procedure

To obtain a copy of a specific publication, users should contact the publication's publisher directly.

Abstract
An interlaboratory "round robin" was conducted for the calibration method developed by ASTM Task Group E 37.01.12,which is described in this paper. The interlaboratory test protocol was consistent with the requirements outlines in ASTM Standard Test Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method (E691). The results obtained by ten participating laboratories are reported. A precision and bias statement for the ASTM Test Method for Temperature Calibration of Thermomechanical Analyzers (E 1363) was developed from the statistical treatment of the data.
Date
9/1991
Author(s)
Rickey Seyler
Page(s)
22-31
Keyword(s)
interlaboratory test; thermomechancail analyzers; TMA; temperature calibration


Note: Documents in this section are provided as Adobe Acrobat PDF files. In order to print and view PDF files, the Adobe Acrobat Reader software/plugin, which runs on Microsoft Windows, Macintosh, OS/2 and various versions of UNIX, must be installed on your computer. Adobe Acrobat Reader is available for download as freeware from Adobe Acrobat's website. Please note that the resolution of on-screen versions is not as high as printed versions of PDF files.