Shop NRCA has the industry resources you need.

A performance approach to the development of criteria for low sloped roof membranes

To obtain a copy of a specific publication, users should contact the publication's publisher directly.

Abstract
Outlines a performance approach for developing criteria for the selection and use of membranes in low-slope roof applications. An overview of previous efforts for applying the performance approach to membrane roofing also is given. A fundamental aspect of the performance approach is that selection criteria are based on an understanding of the requirements necessary for the membrane system to perform acceptably in service. The availability of performance-based criteria would greatly assist in eliminating some of the defects that have plagued low-slope roofing over the years. The approach consists of seven steps, including identification of the key functions to be performed by a roof; identification of attributes essential to satisfactory performance; development of the requirements, criteria, and test methods; and putting in place a feedback mechanism to revise the criteria, if warranted, as new information becomes available on the performance of the system in service. Five key functions associated with the performance of the membrane in a low-slope system are identified, and performance requirements for each function are proposed. These functions are watertightness, maintainability, health and safety, environmental impact, and appearance. Of these five functions, watertightness is the one that directly affects the major problem (i.e., leaks) associated with low-slope roof performance. As a consequence, the majority of the requirements recommended for membrane systems in past studies, as well as in the present report, emphasize this aspect of performance. It is recognized that considerable effort may be needed to develop criteria and test methods for the complete set of attributes of membrane roofing that have been associated with the most problems. Review of data from NRCA's Project Pinpoint indicated that seam defects in single-ply membranes have been the problems most frequently encountered for these types of roof systems. On this basis, it is further suggested that the application of the performance approach to membrane roofing begin with the subject of seams. As an initial step in this direction, an outline of the needed criteria is presented including attributes and suggested requirements. The development of criteria and test methods are reserved for future study.
Date
7/1991
Author(s)
Walter Rossiter Jr; Geoff Frohnsdorff; L Masters; J Martin
Page(s)
147
Keyword(s)
evaluation; low slope roofing; performance criteria; test methods; roof functions; watertightness


Note: Documents in this section are provided as Adobe Acrobat PDF files. In order to print and view PDF files, the Adobe Acrobat Reader software/plugin, which runs on Microsoft Windows, Macintosh, OS/2 and various versions of UNIX, must be installed on your computer. Adobe Acrobat Reader is available for download as freeware from Adobe Acrobat's website. Please note that the resolution of on-screen versions is not as high as printed versions of PDF files.

Advertisement

Subscribe for Updates Join 25,000+ roofing professionals following NRCA

Subscribe to NRCA